Crosland Hill Sandstone

Technical Data Sheet
Crosland Hill Sandstone
Wellfield Quarry, near Huddersfield
Crosland Hill, Huddersfield,West Yorkshire. HD4 7AB
Contact : Johnsons Wellfield Quarries Limited
E-mail: [email protected]
Website : http://www.johnsons-wellfield.co.uk
Tel: +44(0)1484 652311 Fax: +44(0)1484 460007
Grid Reference : SE 117 145
Compiled September 1997 and updated in September 1999 and May 2000

This data sheet was compiled by the Building Research Establishment (BRE). Where possible, data collected in earlier surveys has been used to help interpret the test results. The data sheet was compiled in September 1997 and updated in September 1999 and May 2000 using the results of tests carried out to the proposed European Standards. The work was carried out by BRE as part of a Partners in Technology Programme funded by the Department of the Environment, Transport and the Regions and Johnson Wellfield Quarries Ltd and does not represent an endorsement of the stone by BRE.

General
The quarry is huge. Originally there were three separate quarries, Wellfield, Waterholes and Moorfield. Now the quarry boundaries have been broken through to form one vast quarry. There are extensive reserves of stone. The quarry has been worked by the present owners since 1938. Block sizes of up to 3500 x 1750 x 1500 mm are available along with veneers and paving material up to a maximum of 5.2 m2 ranging from 30 – 100 mm in thickness. There are large reserves of material.

Petrography
Crosland Hill Hard York Stone is from the Millstone Grit of Carboniferous age. It is a fine- to medium-grained stone, buff in colour. The top 3 to 9m of stone are crushed for aggregate. The depth of the face below this varies around the quarry from 7.5 to 9m. The average depth of stone on bed is from 750mm to 900mm with an average length of 2.85m.

Expected Durability and Performance
It is important that the results from the from individual tests are not viewed in isolation. They should be considered together and compared to the performance of the stone in existing buildings and other uses. Sandstones from the Millstone Grit series are traditionally acknowledged as generally being a very durable building and paving stone and have been used extensively in many towns and cities in the UK. Crosland Hill sandstone appears to be a durable stone that is not effected by acid rain or air pollution. In addition, the low weight lost in the saturated sodium sulphate crystallisation test indicates good resistance to salt damage (for example in coastal locations or from de-icing salts. The resistance to frost result indicates that the stone is not affected by the action of freeze thaw and in conjunction with the saturated sodium sulphate crystallisation test indicates that the stone should have good frost resistance. The compressive and flexural strength of the stone is towards the top of the range for UK sandstone. The abrasion resistance is comparable with other York paving stones and should be suitable for use in heavily trafficked areas.

Overall, should be suitable for use in most aspects of construction including flooring, paving, load bearing masonry and cladding including areas where a long service life is needed or where high salt concentrations are expected.

Test Results – Crosland Hill Sandstone

Safety
in Use
Slip Resistance (Note 1)

75-83

 Values > 40 are considered
safe. 
Abrasion Resistance
(Note 1)

19.6 mm

Values <23.0 are considered
suitable for use in heavily trafficked
areas
Strength
under load
1) Compression(Note 2)

132 MPa

Loaded perpendicular
to the bedding plane
ambient humidity
2) Bending (Note 1)

15.0-18.9 MPa

Loaded perpendicular to the
bedding plane
ambient humidity

Not determined

Loaded parallel to the
bedding plane
ambient humidity
Porosity
and Water Absorption
1) Porosity (Note 3)

8.6 – 9.2%

2) Saturation Coefficient (Note 3)

0.60 – 0.68

3) Water Absorption

2.4% (by wt)

4) Bulk specific gravity

2416-2430kg/m3

Resistance to Frost 
Flexural
strength after
Freeze/Thaw Test (Note 1)

14.3 MPa

Loaded perpendicular
to the bedding plane
ambient humidity
Resistance
to Salt
Sodium Sulphate Crystallisation Test
(Note 3)

0.83% Mean wt loss

Sodium Sulphate Crystallisation Test
(Note 3) (saturated solution)

11.3%
Mean wt loss

Resistance to Acidity 
Acid Immersion Test(Note 4)

Pass 

(Test methods Note 1 = EN1341, Note 2 = EN 1342, Note 3 = EN 1341 /BRE 141, Note 4 = BRE 141)

Tests were carried out at BRE in 1997. N.D. = not determined

Return to Stones Glossary